Parameter Min Max Unit
IDMA Read, Short Read Cycle
Timing Requirements:
t
IKR
IACK Low before Start of Read
1
0ns
t
IRP
Duration of Read 15 ns
Switching Characteristics:
t
IKHR
IACK High after Start of Read
1
15 ns
t
IKDH
IAD15–0 Data Hold after End of Read
2
0ns
t
IKDD
IAD15–0 Data Disabled after End of Read
2
10 ns
t
IRDE
IAD15–0 Previous Data Enabled after Start of Read 0 ns
t
IRDV
IAD15–0 Previous Data Valid after Start of Read 15 ns
ADSP-2183
28.8 MHz
Parameter Min Max Unit
IDMA Read, Short Read Cycle
Timing Requirements:
t
IKR
IACK Low before Start of Read
1
0ns
t
IRP
Duration of Read 15 ns
Switching Characteristics:
t
IKHR
IACK High after Start of Read
1
17 ns
t
IKDH
IAD15–0 Data Hold after End of Read
2
0ns
t
IKDD
IAD15–0 Data Disabled after End of Read
2
10 ns
t
IRDE
IAD15–0 Previous Data Enabled after Start of Read 0 ns
t
IRDV
IAD15–0 Previous Data Valid after Start of Read 15 ns
NOTES
1
Start of Read = IS Low and IRD Low.
2
End of Read = IS High or IRD High.
t
IRP
t
IKR
PREVIOUS
DATA
t
IKHR
t
IRDV
t
IKDD
t
IRDE
t
IKDH
IAD 15–0
IACK
IS
IRD
Figure 32. IDMA Read, Short Read Cycle